Building an intelligent training system based on power modules:
1.A multimodal user body adaptive image recognition system.
2.Algorithm for generating and updating user training profiles.
3.Multimodal training and intelligent resistance solution system.
*Looking for agents
Technical Specification of Power Cube |
|
Type | Power Cube-Double Motor |
Control mode | Shuttle knob control Touch display control |
Resistance output mode | Unilatereal output resistance Bilateral merger output resistance Bilateral output resistance |
Resistance (kg) |
Single:2.5-50 Double:5-100 |
Reduction Ratio | 4 |
Input Voltage | AC220 |
Module Size | According to customers |
Power (W) |
750 |
Rated torque (N·m) |
2.39 |
Rated speed (R.P.M.) |
3000 |
Rated current (A) |
3 |
Rated torque after deceleration (N·m) |
9.56 |
Rated speed after deceleration (R.P.M.) |
750 |
Weight of Motor and Reducer (kg) |
4.9 |
Maximum torque to weight ratio (Motor and Reducer) (N·m/kg) |
1.95 |
Maximum power to weight ratio (Motor and Reducer) (kw/kg) |
0.15 |
Rated output force (one side) (kg) |
25.8 |
Rated linear speed of rope return (m/s) |
3.14 |
Take-up reel diameter (mm) |
80.00 |
Module weight (KG) |
23 |
Communication control interface | Serial port |
OTA Function | Supported |
5 model | Supported |
Early warning and protection | Supported |
Resistance recommendation | Supported |
Motor Specifications |
||
Project | Motor type | |
Type 80(750w) | ||
Output unilateral maximum resistance (kg) |
50 | |
Rated output power (W) |
750 | |
Paired with drive | SDV3-2S0.75G | |
Rated torque (N·m) |
2.39 | |
Rated speed (R.P.M.) |
3000 | |
Rated current (A) |
3 | |
Rotor inertia (kg·m²×10-4) |
1.82 | |
Instantaneous maximum torque (N·m) |
7.1 | |
Maximum speed (R.P.M.) |
3600 | |
Maximum torque to weight ratio (N·m/kg) |
2.45 | |
Maximum power to weight ratio (kW/kg) |
0.26 | |
Weight (kg) |
2.9 | |
Insulation class | F Class(155℃) | |
Motor ambient temperature | -20℃~+40℃ | |
Permanent magnet brake | Rated voltage of holding brake (V) |
DC24±10% |
Holding torque of the brake (N·m) |
4 | |
Rated power of holding brake (W) |
18 |
Project |
Drive Technical Specification |
|
Input power supply | Single phase 220v | |
Voltage fluctuation range(-15%~+10%)50/60Hz | ||
Heat dissipation mode | Forced air cooling | |
Control method | Sine-wave drive | |
Feedback | 17 bit encoder | |
Control model | ① Position control ② Speed control ③ Torque control ④ Position/speed mode switching ⑤ Position/torque mode switching ⑥ Speed/torque mode switching ⑦ Positioning operation mode | |
Position control |
Maximum input pulse frequency | Differential input: maximum 500kHz, open collector input: maximum 200kHz |
Command pulse input method | ① Instruction pulse/instruction symbol ② Forward/reverse pulse ③ A/B phase orthogonal pulse | |
Command control method | ① External command pulse input control ② Internal position data control | |
Electronic Gearing | Electronic gear N/M times (N: 1-4194304)/(M: 1-4194304) | |
Torque limit | Parameter control (adjustable for forward and reverse rotation)/external analog torque control | |
Torque control |
Analog command input | VCL DC0~±10V |
Speed limit | Parameter control/external analog speed limit | |
Number input output |
Input | EI1~EI5 5-way inputs, functions can be freely configured through parameters |
Output | Encoder pulse frequency division output, A/B/Z differential output | |
EOUT1~EOUT3 3-way output, function can be freely configured through parameters | ||
Monitoring function | Feedback speed, command speed, command torque, motor current, feedback current position, command current position, position deviation, command pulse frequency, feedback cumulative pulse, command cumulative pulse, VREF input voltage, TREF input voltage, input signal, output signal, etc | |
Protection function (Alarm display) |
Overcurrent (oc1, oc2), overspeed (oS), overvoltage (Hv), memory failure (dE), encoder communication failure (Ec), overload (oL1, oL2), main circuit voltage shortage (Lu), EI repetition (ctE), deviation exceeding (oF), driver overheating (AH), etc | |
Apply environment |
Installation location | Indoor (avoid direct sunlight), without corrosive mist (avoid oil fumes, flammable gases, and dust) |
Ambient temperature | 0~50 ℃ (If the ambient temperature exceeds the specified range, please force the surrounding air circulation) | |
Storage temperature | -20℃~75℃ | |
Humidity | Below 90% RH (without condensation) | |
Elevation | Altitude below 1000m | |
Atmospheric pressure | 86~106kPa | |
Vibration | ≤0.5G |